• Cooling Solution for Vacuum Furnace System
Cooling Solution for Vacuum Furnace System
Vacuum furnace systems mostly use open circulation systems. The system consists of a circulating water pool, cooling water circulation pump, emergency cooling water tank, plate heat exchanger, etc. The key point in the system is to set up a circulating water pool with a large effective volume. This pool is only used as a water pump suction pool when the system is operating normally. In emergency situations such as power outages, when the chiller or cooling tower stops running and cannot provide refrigerant for the vacuum furnace system, the cooling water circulation pump is equipped with emergency power to continue working.
  • Product Detail
  • Product Tags

The vacuum furnace system mostly adopts an open circulation system. The system consists of a circulating water pool, a cooling water circulation pump, an emergency cooling water tank, a plate heat exchanger, etc. The key point in the system is to set up a circulating water pool with a large effective volume. This pool is only used as a water pump suction pool when the system is operating normally. In emergency situations such as power outages, when the chiller or cooling tower stops running and cannot provide refrigerant for the vacuum furnace system, the cooling water circulation pump is equipped with emergency power to continue working, and the water in the pipe network and the pool continues to circulate. Because the specific heat of water is greater than the specific heat of silicon, the water in the circulating water pool is used to absorb the heat of the high-temperature silicon in the ingot furnace, thereby lowering the temperature of the ingot furnace and ensuring that the furnace body will not be damaged or even exploded during a power outage. The water storage capacity of the circulating water pool is determined based on the fact that when the silicon materials in all furnaces in the system are cooled to a safe temperature, the temperature of the water in the pool will not rise to a level that the cooling water system pipe network and equipment cannot tolerate. The cooling water system must be equipped with an emergency power supply for the vacuum furnace circulating water pump. This emergency power supply generally uses a diesel generator. In order to ensure that cooling water still flows through the furnace body before the diesel generator is started, a high-level emergency cooling water tank is generally installed in the vacuum furnace system. When the system is powered off, the water in this water tank relies on gravity to flow through the furnace body to cool the furnace body.

主站蜘蛛池模板: 免费观看黄a一级视频 | 久久久久久亚洲精品视频 | 性色视频免费观看 | 毛片真人毛毛片毛片 | 自拍偷拍欧美 | 91丁香婷婷综合久久欧美 | 欧美日韩精品久久久 | 国产一级一级国产 | 亚洲欧美日韩国产综合 | 亚洲精品久久久久国产 | 久免费视频| 国产精品久久777777 | 中文字幕在线观看一区二区三区 | 国产精品美女视频一区二区三区 | 国产精品美女视频免费观看软件 | 久久蜜桃精品一区二区三区综合网 | 日韩欧美国产网站 | 91免费看 | 久久99精品久久久 | 国产免费av在线 | 国产剧情一区二区 | 亚洲精品国精品久久99热 | 超碰天堂| 久久999免费视频 | 国产亚洲精品美女久久久久久久久久 | 欧美色视 | 欧美黄 片免费观看 | 午夜久久久 | 日本亚洲最大的色成网站www | 国产一区二区三区四区三区 | 97精品国产| 天天天操 | 一区二区三区免费 | 婷婷色综合 | 一区二区在线看 | 久久精av| 欧美午夜三级视频 | 91精品国产91久久久久游泳池 | 亚洲精品一二区 | 久久精品亚洲一区 | 奇米色777欧美一区二区 |